SHOP BY SUB CATEGORY, MANUFACTURER, & PRICE

Sloan Regal Flushometers

ProDryers supplies the full Sloan Regal family for water closets and urinals in commercial and institutional facilities. Regal is a proven diaphragm flushometer line with an ADA compliant non-hold-open handle, precise metering, and installer-friendly details like an adjustable tailpiece and vacuum breaker assembly. Closet models are commonly specified at 1.6 gpf or 1.28 gpf. Urinal models are available at 1.0 gpf, 0.5 gpf, and 0.125 gpf.

Why facilities specify Regal

  • Reliable diaphragm technology engineered for consistent flush volumes
  • ADA compliant non-hold-open handle that prevents over-flushing
  • Chloramine resistant internal components for long service life
  • Rugged brass body and angle stop for heavy commercial use
  • Adjustable tailpiece and vacuum breaker connection for flexible installation

Regal selection at a glance

Application

Spud location

Typical gpf

Actuation

Package notes

Water closet

Top spud

1.6 or 1.28

Manual

Adjustable tailpiece, ADA non-hold-open handle, XL package available

Urinal

Top spud

1.0 or 0.5 or 0.125

Manual

Match volume to fixture rating, XL package available

Closet or urinal

Top spud

Match fixture

Sensor

Factory sensor or side-mount retrofit on compatible bodies

Closet or urinal

Concealed or remote

Match fixture

Hydraulic

Push-button actuation for remote or vandal-resistant layouts

Core Regal configurations

Water closet, exposed manual

Popular exposed top-spud models include the Regal 110 and 111 families. Closet options include 1.6 gpf and high-efficiency 1.28 gpf selections. XL packages include installation hardware such as a sweat-solder adapter kit.

Urinal, exposed manual

Common choices include Regal 180 and 186 families. Flush volumes include 1.0 gpf for low consumption, 0.5 gpf for WaterSense targets when paired with the right fixture, and 0.125 gpf for ultra-low systems.

Touch-free and hydraulic options

Regal is available in factory sensor configurations and can also be upgraded using side-mount sensor operators on compatible manual valves. A hydraulic push-button version is available for remote or concealed actuation where vandal resistance or design constraints call for it.

Selection guidance from our team

  • Match the valve to the fixture. Use the bowl or urinal manufacturer’s rated flush volume to maintain rinse performance.
  • XL package details. XL variants include the sweat-solder adapter and related hardware, which speeds retrofit work on copper stub-outs.
  • Materials and internals. Semi-red brass castings and chloramine resistant diaphragm components help maintain performance in harsh water conditions.
  • Compliance. Use the ADA non-hold-open handle and follow local code for mounting height, clearances, and vacuum breaker positioning.

How to order Regal correctly

  • Choose the valve family for the fixture type and spud location
  • Select the rated flush volume to match the bowl or urinal
  • Pick actuation style and package
  • Confirm stop type, tailpiece length, and vacuum breaker tube length
  • If selecting a sensor configuration, match site voltage and power method
  • Add any installation accessories required by local code

Common retrofit scenarios

  • Replacing existing exposed manual valves on copper supplies using an XL package with a sweat-solder adapter
  • Upgrading manual Regal bodies with a side-mount sensor operator for touch-free operation while retaining a mechanical override
  • Changing urinal volumes from 1.0 to 0.5 gpf only when the fixture is rated for the lower volume
  • Verifying vacuum breaker tube length, spud coupling size, and tailpiece adjustment during replacement to avoid fit issues

Popular models

  • Regal 111 1.6 gpf or 1.28 gpf for exposed closet applications
  • Regal 180 1.0 gpf for standard low-consumption urinals
  • Regal 186 0.5 gpf for WaterSense urinal applications, with 0.125 gpf available for compatible fixtures
  • Regal sensor urinal configurations for hands-free operation with a mechanical override on the body

Maintenance and parts

Regal shares a broad ecosystem of Sloan service parts. Common items include diaphragm kits for specific flow rates, handle repair kits, vacuum breaker assemblies, and angle stop components. Most maintenance can be completed from the front of the valve with standard tools, minimizing downtime.

Why buy Regal from ProDryers

  • Model and code verification against your fixture schedule before shipping
  • Project quoting for one valve or full bid lists, including sensor upgrades and hydraulic options
  • Fast nationwide fulfillment and expert phone support at 888-503-7937

FAQ

What is the difference between Sloan Regal and Royal
Both are diaphragm flushometers. Regal emphasizes cost-effective performance with a non-hold-open handle, precise metering, and widely available parts. Royal is a related line with different internal features and options. Choose based on your specification, legacy stock, and facility standards.

Can I convert existing Regal manual valves to sensor operation
Yes. You can select factory sensor Regal models or retrofit compatible manual bodies using a side-mount sensor operator for touch-free operation while retaining a mechanical override.

What are the most common Regal urinal flush volumes
1.0 gpf is common for low-consumption urinals. 0.5 gpf is used for WaterSense targets when matched to the right fixture. 0.125 gpf is available for ultra-low designs with compatible fixtures.

Do Regal XL packages include installation hardware
Yes. XL versions include a sweat-solder adapter kit and related hardware that simplify retrofit work on copper supplies.